Pumps
Gear, centrifugal, diaphragm, vacuum and metering pumps.
Also searched as: gear pumpcentrifugal pumpdiaphragm pumpvacuum pumpwater pump
-
Diaphragm Pump
Flow Rate: 1.0 GPMVoltage: 12-Volt
Home DepotWholesale price quotes available Request a quote -
Diaphragm Pump
Flow: 2 Ton/H
AliExpressWholesale price quotes available Request a quote -
eBayWholesale price quotes available Request a quote -
FastenalWholesale price quotes available Request a quote -
Diaphragm Pump Repair Kit
Model Compatibility: Metallic G1F Models
FastenalWholesale price quotes available Request a quote -
FastenalWholesale price quotes available Request a quote -
FastenalWholesale price quotes available Request a quote -
Diaphragm Pump for Automatic Filling Machine
Voltage: 12V, 24V
AliExpressWholesale price quotes available Request a quote -
Diaphragm Pump, 4.0 GPM, 12V, with 1/2" fittings
Fittings: 1/2"Flow Rate: 4.0 GPMVoltage: 12V
AmazonWholesale price quotes available Request a quote -
Diaphragm Pump, Med Pressure
Flow Rate: 10.6 Gpm
ZoroWholesale price quotes available Request a quote -
Diaphragm Water Pump
Flow Rate: 2.0-5.0 LPMPressure: 17-120 PSIVoltage: 12V
AliExpressWholesale price quotes available Request a quote -
Diaphragm Water Pump
Flow Rate: 8 l/minPower: 100WVoltage: 12V
AliExpressWholesale price quotes available Request a quote -
eBayWholesale price quotes available Request a quote -
DD
Double Diaphragm Pump
Operation: Air and Electric Operated
GracoWholesale price quotes available Request a quote -
Double Diaphragm Pump, Air Operated
Wet Self-Priming: 28 ft
ZoroWholesale price quotes available Request a quote -
Double Diaphragm Pump, Air Operated
Flow Rate (Maximum): 200 gpmFlow Rate @ 20 psi: 93.3 gpmTemperature: 220 Degrees F
ZoroWholesale price quotes available Request a quote -
Double Diaphragm Pump, Air Operated
Flow Rate: 49 GPM
ZoroWholesale price quotes available Request a quote -
Double Diaphragm Pump, Air Operated
Air Consumption (Maximum): 55 scfmAir Intake Connection Size: 1/4 inFlow Rate (Maximum): None
ZoroWholesale price quotes available Request a quote -
Dual Diaphragm Air Pump, 1 inch Inlet & Outlet, 35 GPM
Flow Rate: 35 GPMInlet: 1 inchOutlet: 1 inch
AmazonWholesale price quotes available Request a quote -
Dual-Stage HVAC Vacuum Pump
Flow Rate: 5.0 CFMStages: Dual
AmazonWholesale price quotes available Request a quote -
Electric Drum Pump
Amperage: 6.3 ADischarge Tube Length: 5 ftMotor: 0.5 HPVoltage: 115 V
UlineWholesale price quotes available Request a quote -
AmazonWholesale price quotes available Request a quote -
Electric Water Centrifugal Pump
HP: 1Inlet/Outlet: 1"Maximum Total Head: 164FtRPM: 3450
AmazonWholesale price quotes available Request a quote -
ZoroWholesale price quotes available Request a quote -
Eliminator 6 CFM Vacuum Pump
Flow Rate: 6 CFMHorsepower: 1/2 HPVoltage: 115V
AmazonWholesale price quotes available Request a quote -
Made-in-ChinaWholesale price quotes available Request a quote -
FM Approved Rotary Drum Pump
Outlet Diameter: 3/4"
UlineWholesale price quotes available Request a quote -
Made-in-ChinaWholesale price quotes available Request a quote -
FastenalWholesale price quotes available Request a quote -
Gear Pump
Displacement: 3.66 CCMPorts: 3Rotation: CCW
Motion IndustriesWholesale price quotes available Request a quote -
Gear Pump
Displacement: 1.5 CIDInlet Port: SAE-16Mounting: 2-Bolt AOutlet Port: SAE-12PSI: 2465
AmazonWholesale price quotes available Request a quote -
Made-in-ChinaWholesale price quotes available Request a quote -
Gear Pump
Air Separation Ability: 20%Flow Rate: 45~55L/minPower: 750-1000WRotary Speed: 800~1000rpm
Made-in-ChinaWholesale price quotes available Request a quote -
AmazonWholesale price quotes available Request a quote -
DanfossWholesale price quotes available Request a quote -
Made-in-ChinaWholesale price quotes available Request a quote
About pumps
Pumps are mechanical devices designed to move fluids, whether liquids, gases, or slurries, by converting mechanical energy into hydraulic energy. They are broadly categorized by their operational principle into positive displacement and kinetic (dynamic) types. Positive displacement pumps, such as gear, diaphragm, and peristaltic pumps, trap a fixed volume of fluid and force it into the discharge pipe. Kinetic pumps, including centrifugal and axial-flow pumps, impart velocity to the fluid through an impeller, then convert that velocity into pressure. Key selection parameters include flow rate (typically in GPM or m³/hr), discharge pressure (PSI or bar), NPSH requirements, and fluid viscosity. Material compatibility is critical, with common construction materials including cast iron, stainless steel (304, 316L), bronze, and various polymers like PTFE or PVDF, chosen based on fluid corrosivity, temperature, and abrasiveness. Seal types, such as mechanical seals, packing, or sealless magnetic drive designs, are specified according to leakage tolerance and fluid characteristics. Drive mechanisms range from electric motors (AC/DC, single/three-phase) to pneumatic or hydraulic power sources, with considerations for RPM and power consumption (HP or kW). Connection types often conform to NPT, BSPT, or flange standards like ANSI B16.5.
How to choose
title: How to Choose a Pump
steps: What fluid is being pumped? Identify its viscosity, temperature, chemical compatibility, and presence of solids. This dictates material selection and pump type.
What flow rate (GPM/m³/hr) and discharge pressure (PSI/bar) are required? This defines the pump's hydraulic performance curve and motor sizing. Consider system head losses.
What is the available Net Positive Suction Head (NPSHa)? Compare this to the pump's NPSH required (NPSHr) to prevent cavitation. Evaluate suction lift or flooded suction conditions.
What power source is available (electric, pneumatic, hydraulic)? Specify voltage, phase, and frequency for electric motors, or air/fluid pressure for others. Consider hazardous area classifications (e.g., ATEX, NEMA).
What level of leakage is acceptable? Select between sealed (mechanical seals, packing) or sealless (magnetic drive, canned motor) designs based on fluid toxicity or value, and maintenance requirements.